Study on the Impacts of Peaking Factors on a Water Distribution System in Germany

dc.cclicenceN/Aen
dc.contributor.authorDiao, Kegongen
dc.contributor.authorBarjenbruch, M.en
dc.contributor.authorBracklow, U.en
dc.date.acceptance2010-02-03en
dc.date.accessioned2016-07-20T10:49:24Z
dc.date.available2016-07-20T10:49:24Z
dc.date.issued2010
dc.description.abstractThis paper aims to explore the impacts of peaking factors on a water distribution system designed for a small city in Germany through model-based analysis. As a case study, the water distribution network was modelled by EPANET and then two specific studies were carried out. The first study tested corresponding system-wide influences on water age and energy consumption if the peaking factors used at design stage are inconsistent with ones in real situation. The second study inspected the possible relationship between the choice of peaking factors and budgets by comparing several different pipe configurations of the distribution system, obtained according to variety of peaking factors. Given the analysis results, the first study reveals that average water age will increase if peaking factors estimated at design stage are larger than real values in that specific system, and vice versa. In contrast, energy consumption will increase if peaking factors defined for system design are smaller than ones in real case, and vice versa. According to the second study, it might be possible to amplify peaking factors for design dramatically by a slight increase in the investment on this system. However, further study on budget estimation with more factors and detailed information considered should be carried out.en
dc.funderErasmus Mundus, Technische Universität Berlinen
dc.identifier.citationDiao, K., Barjenbruch M. and Bracklow U. (2010) Study on the Impacts of Peaking Factors on a Water Distribution System in Germany. Water Science and Technology: Water Supply, 10 (2), pp. 165–172.en
dc.identifier.doihttps://doi.org/10.2166/ws.2010.168
dc.identifier.urihttp://hdl.handle.net/2086/12320
dc.language.isoenen
dc.peerreviewedYesen
dc.projectidN/Aen
dc.publisherIWA Publishingen
dc.researchinstituteInstitute of Energy and Sustainable Development (IESD)en
dc.subjectbudgeten
dc.subjectmodellingen
dc.subjectpeaking factorsen
dc.subjectwater ageen
dc.subjectwater demanden
dc.subjectwater distribution systemen
dc.titleStudy on the Impacts of Peaking Factors on a Water Distribution System in Germanyen
dc.typeArticleen

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
WSTWS_10_168.pdf
Size:
228.13 KB
Format:
Adobe Portable Document Format
Description:
Main article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.2 KB
Format:
Item-specific license agreed upon to submission
Description: