Applying the FSV (Feature Selective Validation) method to the comparison of switching for Signal Integrity applications

Date

2021

Advisors

Journal Title

Journal ISSN

ISSN

2637-6423

DOI

Volume Title

Publisher

IEEE

Type

Article

Peer reviewed

Yes

Abstract

To ensure good signal integrity design, there are a number of design principles that should be applied, including avoiding any breaks in a current return path, e.g. a ground plane in a multilayer stack up. Occasionally, these guidelines are not followed: possibly through necessity or convenience. However, it is helpful to the designer to understand the impact of such factors that might influence the quality of the digital signal being transmitted. Typically, such an analysis might be undertaken using eye diagrams but it is more difficult to perform comparative testing on single transitions. This paper applies the FSV method, using the modified transient analysis approach, to single transitions for a PCB track having its return path influenced by a break in the return plane; in this case, the break is a circular ‘gap’ in the ground plane. FSV’s global difference measure is used to quantify the effects of the amount of overlap of the signal track with the gap. The paper illustrates how the modified transient FSV approach can help provide quantified supporting information for the SI designer.

Description

The file attached to this record is the author's final peer reviewed version

Keywords

Signal integrity, Feature Selective Validation method, transient

Citation

Zhang, G. and Duffy, A. (2021) Applying the FSV (Feature Selective Validation) method to the comparison of switching for Signal Integrity applications. IEEE Letters on Electromagnetic Compatibility Practice and Application,

Rights

Research Institute