Development of a Manual Measurement Device for Measuring Hallux Valgus Angle in Patients with Hallux Valgus

dc.cclicenceCC BYen
dc.contributor.authorLi, Guoli
dc.contributor.authorShen, Jinsong
dc.contributor.authorSmith, Edward
dc.contributor.authorPatel, Chetna
dc.date.acceptance2022-07-19
dc.date.accessioned2022-08-15T09:29:25Z
dc.date.available2022-08-15T09:29:25Z
dc.date.issued2022-07-26
dc.descriptionopen access articleen
dc.description.abstractBackground: Hallux valgus (HV) is one of the most common forefoot deformities, and its prevalence increases with age. HV has been associated with poor foot function, difficulty in fitting footwear and poor health-related quality of life. The aims of this study were to design and develop an easy-to-use measurement device for measuring hallux valgus angle (HVA) in patients with HV and to assess the measurement reliability of the newly designed measurement device. Methods: A manual measurement device for measuring HVA was designed and developed to test on patients with HV. Two measuring methods, i.e., test–retest and intra-observer measurements, were used to evaluate the repeatability and reliability of the newly designed measurement device. In the test–retest measurements, a total of 42 feet from 26 patients with HV were repeatedly measured by the same researcher using the manual measurement device every 3 weeks over a period of 12 months. The measurement reliability of the newly designed measurement device was analysed based on the collected HVA data. In the intra-observer measurements, a total of 22 feet from the same group of HV patients were measured by the same researcher using the manual measurement device and by a consultant using X-ray measurement for comparison. The intraclass correlation coefficient (ICC) was used to determine the correlation of measurements between the manual measurement device and X-ray measurement. Results: The mean of the difference between the two repeat measurements of HVA using the newly designed manual device was 0.62°, and the average of ICC was 0.995, which indicates excellent reliability. The ICC between X-ray and the average of twice-repeated manual measurements was 0.868, with 95% CI (0.649, 0.947) (p = 0.000). When the relationship in HVA between X-ray measurement and manual measurement using the new device was regressed as a linear relationship, the regression equation was y = 1.13x - 4.76 (R2 = 0.70). Conclusions: The newly designed measurement device is easy to use, with low-cost and excellent reliability for HVA measurement, with the potential for use in clinical practice.en
dc.funderOther external funder (please detail below)en
dc.funder.otherThe Scientific Research Projects of Guangdong Provincial Department of Education (grant number 2020KTSCX284)en
dc.funder.otherThis research wasThe Research Project of Academic Innovation team of Guangzhou Panyu Polytechnic (grant number 2020CXTD006).en
dc.identifier.citationLi, G., Shen, J., Smith, E., Patel, C. (2022) Development of a Manual Measurement Device for Measuring Hallux Valgus Angle in Patients with Hallux Valgus. International Journal of Environmental Research and Public Health, 19 (15), 9108en
dc.identifier.doihttps://doi.org/10.3390/ijerph19159108
dc.identifier.urihttps://hdl.handle.net/2086/22112
dc.language.isoenen
dc.peerreviewedYesen
dc.publisherMDPIen
dc.researchinstituteInstitute of Art and Designen
dc.subjectRadiograph measurementen
dc.subjectmanual measurementen
dc.subjecthallux valgus angular measurementen
dc.subjectmanual measurement deviceen
dc.subjectreliabilityen
dc.titleDevelopment of a Manual Measurement Device for Measuring Hallux Valgus Angle in Patients with Hallux Valgusen
dc.typeArticleen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ijerph-19-09108-v2 ppublished.pdf
Size:
1.59 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.2 KB
Format:
Item-specific license agreed upon to submission
Description: