Abstract
Description
This output presents implementation results from EPSRC grant (GR/M67360, £108k), “Optimised Pressure Control for Networks with Multiple Pressure Reducing Valves Inputs” and the follow-on EPSRC RAIS grant (GR/S14382). The findings were implemented by South Staffordshire Water Company in 15 district metering areas reducing water losses by 20% (Nigel Shipley, South Staffordshire Water, nigelshipley@south-staffordshire.com). Similar strategies are now being implemented by Yorkshire Water and United Utilities as an aspect of the EPSRC NEPTUNE project (EP/E003192/1, www.neptune.ac.uk/). Follow on paper “Improved Control of Pressure Reducing Valves in Water Distribution Networks” will be published in Journal of Hydraulic Engineering, vol. 134(1) January, 2008.
Keywords
RAE 2008, UoA 28 Mechanical, Aeronautical and Manufacturing Engineering
Citation
Ulanicki, B., Prescott, S.L. and Shipley, N. (2003) Analysis of district metered areas (DMAs) performance. Adavnces in water supply management proceedings of the CCWI2003, pp. 59-67