Show simple item record

dc.contributor.authorBernieh, Dennisen
dc.contributor.authorLawson, Grahamen
dc.contributor.authorTanna, Sangeetaen
dc.date.accessioned2015-09-16T09:34:40Z
dc.date.available2015-09-16T09:34:40Z
dc.date.issued2015-07-03
dc.identifier.citationBernieh, D., Lawson, G. and Tanna, S. (2015) Can quantitative dried blood spot analyses be an aid to medicine optimization in cardiovascular diseases? Proceedings of the Analytical Research Forum (ARF) 2015en
dc.identifier.urihttp://hdl.handle.net/2086/11206
dc.description.abstractIntroduction: Over 355 million prescriptions were dispensed for cardiovascular diseases in the UK in 2013 [1]. Half of these, costing the NHS £2.3 billion, were wasted because patients do not take their medicines as prescribed [2]. A method using dried blood spot (DBS) sample collection followed by liquid chromatography-high resolution mass spectrometry (LC-HRMS) [3] was developed and validated for quantification of eleven commonly UK prescribed cardiovascular drugs: amlodipine, atenolol, atorvastatin, bisoprolol, diltiazem, doxazosin, lisinopril, losartan, ramipril, simvastatin and valsartan. Thus medication efficiency, adherence or drug/drug interactions can be assessed from reference pharmacokinetic data. Methods: For the preparation of DBS calibration samples whole blood was spiked with eleven target analytes to produce 30µl blood spots on specimen cards. 8mm disc was punched out and extracted with methanol:water (70:30v/v) containing the internal standard, atenolol D7. Chromatography analysis was performed using gradient elution with a run time of 2.5 min. MS detection was carried out in electrospray positive ion mode for all target analytes and internal standard. Results: The LC-HRMS method showed good linearity and the accuracy (relative error) and precision (coefficient of variation) values were within the pre-defined limits of ≤15% at all tested concentrations for eight of the target drugs. Drug recoveries from spiked blood spots were ≥ 82% for atenolol, bisoprolol, diltiazem, doxazosin, losartan, ramipril and valsartan. Results from volunteers were within expected levels except where elevated levels indicated a recognised drug/drug interaction. Conclusions: Quantitative DBS analyses can be used as a means to optimize medication for heart disease patients.en
dc.language.isoenen
dc.publisherThe Royal Society of Chemistryen
dc.subjectmedication adherenceen
dc.subjectdried blood spotsen
dc.subjectLC-HRMSen
dc.titleCan quantitative dried blood spot analyses be an aid to medicine optimization in cardiovascular diseases?en
dc.typeConferenceen
dc.researchgroupPharmacy Practiceen
dc.peerreviewedYesen
dc.funderDMU bursaryen
dc.projectidblood spot analysis researchen
dc.researchinstituteLeicester Institute for Pharmaceutical Innovation - From Molecules to Practice (LIPI)en


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record