Repository logo
  • Log In
Repository logo
  • Communities & Collections
  • All of DORA
  • Log In
  1. Home
  2. Browse by Author

Browsing by Author "Kairamkonda, V."

Now showing 1 - 2 of 2
Results Per Page
Sort Options
  • No Thumbnail Available
    ItemMetadata only
    Dexamethasone quantification in dried blood spot samples using LC-MS: The potential for application to neonatal pharmacokinetic studies.
    (Elsevier, 2010) Patel, Parul; Tanna, Sangeeta; Mulla, Hussain; Kairamkonda, V.; Pandya, Hitesh; Lawson, Graham
    A high-performance liquid chromatography (LC-MS) method has been developed and validated for the determination of dexamethasone in dried blood spot (DBS) samples. For the preparation of DBS samples whole blood spiked with analyte was used to produce 30µl blood spots on specimen collection cards. An 8mm disc was cut from the dried blood spot and extracted using a combination of methanol: water (70:30, v/v) containing the internal standard, triamcinolone acetonide. Extracts were centrifuged and chromatographic separation was achieved using a Zorbax Eclipse Plus C18 column using gradient elution with a mobile phase of acetonitrile and water with formic acid at a flow rate of 0.2ml/min. LC-MS detection was conducted with single ion monitoring using target ions at m/z 393.1 for dexamethasone and 435.1 for the internal standard. The developed method was linear within the tested calibration range of 15-800ng/ml. The overall extraction recovery of dexamethasone from dried blood spot samples was 99.3% (94.3-105.7%). The accuracy (relative error) and precision (coefficient of variation) values were within the pre-defined limits of ≤15% at all concentrations. Factors with potential to affect drug quantification measurements such as blood haematocrit, the volume of blood applied onto the collection card and spotting device were investigated. Although a haematocrit related effect was apparent, the assay accuracy and precision values remained within the 15% variability limit with fluctuations in haematocrit of ± 5%. Variations in the volume of blood spotted did not appear to affect the performance of the developed assay. Similar observations were made regarding the spotting device used. The methodology has been applied to determine levels of dexamethasone in DBS samples collected from a premature neonate. The measured concentrations were successfully evaluated using a simple 1 compartment pharmacokinetic model. Requiring only a microvolume (30µl) blood sample for analysis, the developed assay is particularly suited to pharmacokinetic studies involving paediatric populations.
  • No Thumbnail Available
    ItemMetadata only
    Dried blood spots and sparse sampling: A practical approach to estimating pharmacokinetic parameters of caffeine in preterm infants
    (Wiley, 2013) Patel, Parul; Mulla, Hussain; Kairamkonda, V.; Spooner, N.; Gade, S.; Della Pasqua, O.; Field, D. J.; Pandya, Hitesh
Quick Links
  • De Montfort University Home
  • Library Learning Services
  • DMU Figshare (DMU's Data Repository)
Useful Links
  • Submission Guide
  • DMU Open Access Libguide
  • Take Down Policy
  • Connect with DORA

Kimberlin Library

De Montfort University
The Gateway
Leicester, LE1 9BH
0116 257 7042
justask@dmu.ac.uk

DSpace software copyright © 2002-2025 LYRASIS

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback