Application to Real Power Networks of a Method to Locate Partial Discharges Based on Electromagnetic Time Reversal

dc.cclicenceCC-BY-NCen
dc.contributor.authorRagusa, Antonella
dc.contributor.authorSasse, Hugh G.
dc.contributor.authorDuffy, A. P.
dc.contributor.authorRubinstein, Marcos
dc.date.acceptance2021-09-18
dc.date.accessioned2021-11-11T09:38:08Z
dc.date.available2021-11-11T09:38:08Z
dc.date.issued2021-09-24
dc.descriptionThis work was supported by the European Union’s Horizon 2020 Research and Innovation Programme under the Marie Skłodowska-Curie Grant under Agreement 838681.en
dc.description.abstractThe paper presents an experimental validation of a method to locate partial discharges (PDs) on power distribution and transmission networks. The method is based on electromagnetic time reversal (EMTR) theory, and it uses a Transmission Line Matrix (TLM) model to describe the propagation of the PD signals in the reversed time. Since PDs are regarded as a symptom of insulation degradation, on-line PD location is considered an important approach to monitoring the integrity of a power distribution network, with the aim of detecting and preventing faults and improving network reliability. In this paper, the EMTR-based method is described and its effectiveness in PD localization using only one measurement point is demonstrated in three real 33 kV power lines. Its effectiveness is proved with and without an on-line electromagnetically noisy environment, and its accuracy is evaluated with respect to different signal-to-noise ratio (SNR) levels of the networks. The validation shows that the method is able to locate PDs with an error of 0.14% with respect to the total length of the line in the absence of noise, and with an error that is always lower than 0.5% for an SNR down to -7 dB.en
dc.funderEuropean Union (EU) Horizon 2020en
dc.identifier.citationRagusa, A., Sasse, H.G., Duffy, A. and Rubinstein, M. (2021) Application to Real Power Networks of a Method to Locate Partial Discharges Based on Electromagnetic Time Reversal. IEEE Transactions on Power Delivery, 37 (4), pp. 2738 - 2746en
dc.identifier.doihttps://doi.org/10.1109/TPWRD.2021.3115453
dc.identifier.issn1937-4208
dc.identifier.urihttps://dora.dmu.ac.uk/handle/2086/21434
dc.language.isoenen
dc.peerreviewedYesen
dc.projectidMSCA-IF project, acronym emiT, number 838681.en
dc.publisherIEEEen
dc.researchinstituteInstitute of Engineering Sciences (IES)en
dc.subjectCable systemen
dc.subjectpartial dischargesen
dc.subjectfault preventionen
dc.subjectelectromagnetic time reversalen
dc.subjectpower system protectionen
dc.subjectreliabilityen
dc.subjectTLM modelingen
dc.titleApplication to Real Power Networks of a Method to Locate Partial Discharges Based on Electromagnetic Time Reversalen
dc.typeArticleen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
TPWRD3115453.pdf
Size:
747.48 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.2 KB
Format:
Item-specific license agreed upon to submission
Description: