    ANN application to modelling and control of small absorption chillers
    (2012) Labus, Jerko; Korolija, Ivan; Marjanovic-Halburd, Ljiljana; Zhang, Yi; Coronas, Alberto
    The main aim of this paper is to demonstrate the application of Artificial Neural Networks (ANN) in small absorption chillers modelling and their control optimisation. The Genetic Algorithms (GA) optimisation method was coupled to the ANN model in order to solve the optimal operation problem where the objective function was the minimal primary energy consumption. This paper analyses the impact of control strategy on energy performance of small capacity absorption chillers, while emphasizing the usability of ANN model, and comparing this strategy to conventional operation strategies.
  • No Thumbnail Available
    ItemMetadata only
    The Influence of Weather Conditions on Energy Performance of HVAC System and Absorption Cooling System Coupling
    (2010) Labus, Jerko; Korolija, Ivan; Marjanovic-Halburd, Ljiljana; Coronas, Alberto
    In this study, the attention is focused on the influence of climate conditions and absorption chiller configurations on the energy performance of heating, ventilating and air conditioning (HVAC) systems. We will analyze the correlation between HVAC system dynamic load profile and the performance of various absorption cooling system configurations for two typical European climates: Mediterranean (more specific Spain) and Mild Atlantic Climate (UK). Dynamic simulation software EnergyPlus is used to calculate HVAC system cooling demand of typical narrow plan office building, equipped with variable air volume (VAV) system and placed in chosen climate regions. This cooling demand has been coupled with different absorption cooling system configurations developed in MatLab in order to analyze absorption chiller heat energy consumption. Preliminary results of this study shows that energy savings in terms of heat supply can be achieved when multiple absorption chillers are used. Spanish case study shows that up to 4.9% can be saved while in the UK savings go up to 6.17% when compared with basic scenario which is a single absorption chiller plant. The results also indicate that for the same building type, the combined influence of climate and national standards can produce up to four times higher cooling demand for building in Spain when compared with buildings in the UK. This directly affects the size of the absorption chiller plant which is 50% bigger and the number of hours when chillers are operating which is twice higher.
Quick Links
  • De Montfort University Home
  • Library Learning Services
  • DMU Figshare (DMU's Data Repository)
Useful Links
  • Submission Guide
  • DMU Open Access Libguide
  • Take Down Policy
  • Connect with DORA

Kimberlin Library

De Montfort University
The Gateway
Leicester, LE1 9BH
0116 257 7042
justask@dmu.ac.uk

DSpace software copyright © 2002-2025 LYRASIS

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback